UES65CZ-SPA
- Meets medical safety certification
- 2 MOPP isolation protection
- Leakage current ≤ 100μA
- Energy Efficiency level VI
- Standby power consumption≤0.15W
- Peak load: 140W max @ rated input voltage
- Working altitude 5000 meters
- 4 AC interfaces
Product Features
| Input voltage | 90-264VAC | Working temp. | -30~70℃ (refer to the derating curve for 40~70℃) |
| Input Current | 1.8A, under 90VAC input condition | Storage temperature | -40 ~ 85℃ |
| Standby power consumption | 0.15W MAX | (I.e. | Under non-concentrated conditions, humidity 10%~90% |
| mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 50,000 hours (according to MIL-HDBK-217 standard) | ||
| weight | 260g | Mechanical specifications | 110.5(L) 56.5(W) 31.0(H)mm |
| Application places | Suitable for medical and information equipment power adapters | Safety standards |
|
| model | Voltage (V) | Current (A) | power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES65CZ-XXXYYYSPA | 12.0 | 0.01-5.0 | 60 | 200 | ± 5% | Linear adjustment rate: ±1% Load regulation: ±5% | 88.0% | ≤3s |
| 12.1-13.0 | 0.01-4.61 | 60 | 200 | ± 5% | 88.0% | ≤3s | ||
13.1-14.0 | 0.01-4.28 | 60 | 200 | ± 5% | 88.0% | ≤3s | ||
| 14.1-15.0 | 0.01-4.00 | 60 | 200 | ± 5% | 88.0% | ≤3s | ||
| 19.0 | 0.01-3.42 | 65 | 200 | ± 5% | 88.0% | ≤3s | ||
| 19.1-20.0 | 0.01-3.25 | 65 | 240 | ± 5% | 88.0% | ≤3s | ||
| 20.1-21.0 | 0.01-3.09 | 65 | 240 | ± 5% | 88.0% | ≤3s | ||
| 21.1-22.0 | 0.01-2.95 | 65 | 240 | ± 5% | 88.0% | ≤3s | ||
| 22.1-23.0 | 0.01-2.82 | 65 | 240 | ± 5% | 88.0% | ≤3s | ||
| 23.1-24.0 | 0.01-2.71 | 65 | 240 | ± 5% | 88.0% | ≤3s |
| Input voltage | 90-264VAC | Working temp. | -30~70℃ (refer to the derating curve for 40~70℃) |
| Input Current | 1.8A, under 90VAC input condition | Storage temperature | -40 ~ 85℃ |
| Standby power consumption | 0.15W MAX | (I.e. | Under non-concentrated conditions, humidity 10%~90% |
| mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 50,000 hours (according to MIL-HDBK-217 standard) | ||
| weight | 260g | Mechanical specifications | 110.5(L) 56.5(W) 31.0(H)mm |
| Application places | Suitable for medical and information equipment power adapters | Safety standards |
|
| model | Voltage (V) | Current (A) | power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES65CZ-XXXYYYSPA | 12.0 | 0.01-5.0 | 60 | 200 | ± 5% | Linear adjustment rate: ±1% Load regulation: ±5% | 88.0% | ≤3s |
| 12.1-13.0 | 0.01-4.61 | 60 | 200 | ± 5% | 88.0% | ≤3s | ||
13.1-14.0 | 0.01-4.28 | 60 | 200 | ± 5% | 88.0% | ≤3s | ||
| 14.1-15.0 | 0.01-4.00 | 60 | 200 | ± 5% | 88.0% | ≤3s | ||
| 19.0 | 0.01-3.42 | 65 | 200 | ± 5% | 88.0% | ≤3s | ||
| 19.1-20.0 | 0.01-3.25 | 65 | 240 | ± 5% | 88.0% | ≤3s | ||
| 20.1-21.0 | 0.01-3.09 | 65 | 240 | ± 5% | 88.0% | ≤3s | ||
| 21.1-22.0 | 0.01-2.95 | 65 | 240 | ± 5% | 88.0% | ≤3s | ||
| 22.1-23.0 | 0.01-2.82 | 65 | 240 | ± 5% | 88.0% | ≤3s | ||
| 23.1-24.0 | 0.01-2.71 | 65 | 240 | ± 5% | 88.0% | ≤3s |