UES65CZ-SPA

  • Meets medical safety certification
  • 2 MOPP isolation protection
  • Leakage current ≤ 100μA
  • Energy Efficiency level VI
  • Standby power consumption≤0.15W
  • Peak load: 140W max @ rated input voltage
  • Working altitude 5000 meters
  • 4 AC interfaces
Product Features
Input voltage90-264VACWorking temp.-30~70℃ (refer to the derating curve for 40~70℃)
Input Current1.8A, under 90VAC input conditionStorage temperature-40 ~ 85℃
Standby power consumption0.15W MAX(I.e.Under non-concentrated conditions, humidity 10%~90%
mean time between failuresAt an ambient temperature of 25°C, the mean time between failures at maximum load is 50,000 hours (according to MIL-HDBK-217 standard)
weight260gMechanical specifications110.5(L)  56.5(W)  31.0(H)mm
Application placesSuitable for medical and information equipment power adaptersSafety standards
  • CB( IEC60601-1)
  • TUV -SUD-Mark(EN60601-1 )
  • NRTL(ANSI/AAMI ES60601-1/CAN/CSA C22.2 NO.60601-1)
model

Voltage

(V)

Current

(A)

power

(W)

Ripple
(maximum)
mVpk-pk
Voltage toleranceLinear and Negative Adjustment RatesAverage efficiencyStart delay time
UES65CZ-XXXYYYSPA12.00.01-5.060200± 5%

Linear adjustment rate: ±1%

Load regulation: ±5%

88.0%≤3s
12.1-13.00.01-4.6160200± 5%88.0%≤3s

13.1-14.0

0.01-4.2860200± 5%88.0%≤3s
14.1-15.00.01-4.0060200± 5%88.0%≤3s
19.00.01-3.4265200± 5%88.0%≤3s
19.1-20.00.01-3.2565240± 5%88.0%≤3s
20.1-21.00.01-3.0965240± 5%88.0%≤3s
21.1-22.00.01-2.9565240± 5%88.0%≤3s
22.1-23.00.01-2.8265240± 5%88.0%≤3s
23.1-24.00.01-2.7165240± 5%88.0%≤3s
Input voltage90-264VACWorking temp.-30~70℃ (refer to the derating curve for 40~70℃)
Input Current1.8A, under 90VAC input conditionStorage temperature-40 ~ 85℃
Standby power consumption0.15W MAX(I.e.Under non-concentrated conditions, humidity 10%~90%
mean time between failuresAt an ambient temperature of 25°C, the mean time between failures at maximum load is 50,000 hours (according to MIL-HDBK-217 standard)
weight260gMechanical specifications110.5(L)  56.5(W)  31.0(H)mm
Application placesSuitable for medical and information equipment power adaptersSafety standards
  • CB( IEC60601-1)
  • TUV -SUD-Mark(EN60601-1 )
  • NRTL(ANSI/AAMI ES60601-1/CAN/CSA C22.2 NO.60601-1)
model

Voltage

(V)

Current

(A)

power

(W)

Ripple
(maximum)
mVpk-pk
Voltage toleranceLinear and Negative Adjustment RatesAverage efficiencyStart delay time
UES65CZ-XXXYYYSPA12.00.01-5.060200± 5%

Linear adjustment rate: ±1%

Load regulation: ±5%

88.0%≤3s
12.1-13.00.01-4.6160200± 5%88.0%≤3s

13.1-14.0

0.01-4.2860200± 5%88.0%≤3s
14.1-15.00.01-4.0060200± 5%88.0%≤3s
19.00.01-3.4265200± 5%88.0%≤3s
19.1-20.00.01-3.2565240± 5%88.0%≤3s
20.1-21.00.01-3.0965240± 5%88.0%≤3s
21.1-22.00.01-2.9565240± 5%88.0%≤3s
22.1-23.00.01-2.8265240± 5%88.0%≤3s
23.1-24.00.01-2.7165240± 5%88.0%≤3s

Additional information

Related Products
model
Output Voltage
Output Current
power
Application industry
Data sheet
Compared
UES60L1-SPAC 24V was added to 0.01-2.50A 60W Medical/Home Appliance Industry
UES60LCP-200300SPC 5V/9V/12V/15V/20V was added to 0.01-3.00A 60W Charger
UES60D1-200300SPC 5V/9V/12V/15V/20V was added to 0.01-3.00A 60W Charger
UES60LCP2-SPA 12-15V/19-24V was added to 0.01-5.00A 60W Medical/I.T.E.
UES65-SPAZ 9-24V/48-54V was added to 0.01-5.42A 65W Communications/Medical Industry
UES65B1-SPA 11-18V/19-24V was added to 0.01-5.00A 65W Home appliances/medical industry
UES65CZ-SPA 11-18V/19-24V was added to 0.01-5.00A 65W Medical industry
UES65LZ2-SPC 5V/9V/12V/15V/20V was added to 0.01-3.25A 65W Charger
UES65-SPA5-OP 5-48V was added to 0.01-10.0A 65W Medical/I.T.E.