UES120-SPAZ-OP

  • Compliant with communications and medical safety certifications
  • 2 MOPP isolation protection
  • Leakage current ≤ 100
  • Energy Efficiency level VI 
  • Standby power consumption≤0.5W
  • Working altitude 5000 meters
  • Peak load: 125% rated load @230Vac
  • Convection cool
Product Features
Input voltage85-264VAC (85-115VAC reference derating curve)Working temp.-30~85℃ (40-85℃ refer to derating curve)      
Input Current2.0A, under 100VAC input conditionStorage temperature-40 ~ 85℃        
Output voltage range± 5%Working humidity5~90% RH, non-condensing       
Standby power consumption0.5Wmean time between failures>1000,000hrs Telcordia_SR-332, at 25°C ambient temperature.       
weightAbout 130gMechanical specifications76.2(L)  50.8(W)  31(H)mm      
Application placesSuitable for oral irrigators, oxygen concentrators, ventilators, defibrillators, etc.Safety standardsMeet CB(IEC60601-1)、TUV Mark(EN60601-1)、NRTL(ANSI/AAMI ES60601-1,CAN/CSA-C22.0NO.60601-1)      
            
model

Voltage

(V)

Current

(A)

power

(W)

Ripple
(maximum)
mVpk-pk
Voltage toleranceLinear and Negative Adjustment RatesAverage efficiencyStart delay time
UES120-XXXYYYSPAZ-OP12.0010.00120.00150± 5%Linear adjustment rate: ± 1%
Load: ± 2%
92 %≤3s
15.008.00120.0015092 %≤3s
18.006.66119.8818093 %≤3s
19.006.31119.8918093 %≤3s
24.005.00120.0024093 %≤3s
27.004.44119.8830093 %≤3s
36.003.33119.8830094 %≤3s
48.002.50120.0040095 %≤3s
54.002.22119.8840095 %≤3s
Input voltage85-264VAC (85-115VAC reference derating curve)Working temp.-30~85℃ (40-85℃ refer to derating curve)      
Input Current2.0A, under 100VAC input conditionStorage temperature-40 ~ 85℃        
Output voltage range± 5%Working humidity5~90% RH, non-condensing       
Standby power consumption0.5Wmean time between failures>1000,000hrs Telcordia_SR-332, at 25°C ambient temperature.       
weightAbout 130gMechanical specifications76.2(L)  50.8(W)  31(H)mm      
Application placesSuitable for oral irrigators, oxygen concentrators, ventilators, defibrillators, etc.Safety standardsMeet CB(IEC60601-1)、TUV Mark(EN60601-1)、NRTL(ANSI/AAMI ES60601-1,CAN/CSA-C22.0NO.60601-1)      
            
model

Voltage

(V)

Current

(A)

power

(W)

Ripple
(maximum)
mVpk-pk
Voltage toleranceLinear and Negative Adjustment RatesAverage efficiencyStart delay time
UES120-XXXYYYSPAZ-OP12.0010.00120.00150± 5%Linear adjustment rate: ± 1%
Load: ± 2%
92 %≤3s
15.008.00120.0015092 %≤3s
18.006.66119.8818093 %≤3s
19.006.31119.8918093 %≤3s
24.005.00120.0024093 %≤3s
27.004.44119.8830093 %≤3s
36.003.33119.8830094 %≤3s
48.002.50120.0040095 %≤3s
54.002.22119.8840095 %≤3s

Additional information

Related Products
model
Output Voltage
Output Current
power
Application industry
Data sheet
Compared
UES120DZ-SPA 11-54V 0.01-10.0A 120W Communications/Medical Industry
UED120-SPA 19-24V 0.01-6.32A 120W Communications/Medical Industry
UES120-SPAZ-OP 12V/15V/18V/19V/24V/27V/36V/48V/54V 0.01-10.0A 120W Medical/I.T.E.
UES120-SPA-OP 24V 0.01-5.00A 120W I.T.E.
UES130DZ-SPA 54V 0.01-2.4A 130W I.T.E.