UES60LCP2-SPA
- Compliant with communications, medical safety certifications
- 2 MOPP isolation protection
- Leakage current ≤ 100μA
- Standby power consumption≤0.15W
- 12V to 24V output, up to 60W
- Working altitude 5000 meters
- Interchangeable plug
Product Features
| Input voltage | 80-264VAC | Working temp. | 0 ~ 40 ℃ | |
| Input Current | 1.7A,In 80VAC under input conditions | Storage temperature | -5 ~ 60℃ | |
| Working altitude | DOE VI & CoC V5 Tier2(2016) | (I.e. | 10~90%RH, no condensation | |
| Standby power consumption | 0.15W MAX | mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard) | |
| weight | 220g | Mechanical specifications | 90.5(L) 33.5(W) 58.5(H)mm | |
| Application places | Suitable for charging communication, medical and other equipment | Safety standards | CE(EN62368-1)、CB(IEC62368-1/ IEC60601-1/60601-1-11)、CCC(GB4943.1)、FCC(PART 15)、UL( ANSI / AAMI ES60601-1/60601-1-11/CAN / CSA-C22.2 NO。60601-1/UL62368)、TuV SUD/Mark(EN60601-1/EN60601-1-11)、TuV SUD/ GS( EN62368-1) | |
| model | Voltage (V) | Current (A) | power | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES60LCP2-XXXYYYSPA | 12.0 | 0.01-5.00 | 60.00 | 200 | ± 5% | Linear adjustment rate: ± 1% Load: ± 5% | 89.00 % | ≤3s |
| 12.1-13.0 | 0.01-4.60 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 13.1-14.0 | 0.01-4.28 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 14.1-15.0 | 0.01-4.00 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 19.0 | 0.01-3.15 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 19.1-20.0 | 0.01-3.00 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 20.1-21.0 | 0.01-2.85 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 21.1-22.0 | 0.01-2.72 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 22.1-23.0 | 0.01-2.60 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 23.1-24.0 | 0.01-2.50 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s |
| Input voltage | 80-264VAC | Working temp. | 0 ~ 40 ℃ | |
| Input Current | 1.7A,In 80VAC under input conditions | Storage temperature | -5 ~ 60℃ | |
| Working altitude | DOE VI & CoC V5 Tier2(2016) | (I.e. | 10~90%RH, no condensation | |
| Standby power consumption | 0.15W MAX | mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard) | |
| weight | 220g | Mechanical specifications | 90.5(L) 33.5(W) 58.5(H)mm | |
| Application places | Suitable for charging communication, medical and other equipment | Safety standards | CE(EN62368-1)、CB(IEC62368-1/ IEC60601-1/60601-1-11)、CCC(GB4943.1)、FCC(PART 15)、UL( ANSI / AAMI ES60601-1/60601-1-11/CAN / CSA-C22.2 NO。60601-1/UL62368)、TuV SUD/Mark(EN60601-1/EN60601-1-11)、TuV SUD/ GS( EN62368-1) | |
| model | Voltage (V) | Current (A) | power | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES60LCP2-XXXYYYSPA | 12.0 | 0.01-5.00 | 60.00 | 200 | ± 5% | Linear adjustment rate: ± 1% Load: ± 5% | 89.00 % | ≤3s |
| 12.1-13.0 | 0.01-4.60 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 13.1-14.0 | 0.01-4.28 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 14.1-15.0 | 0.01-4.00 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 19.0 | 0.01-3.15 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 19.1-20.0 | 0.01-3.00 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 20.1-21.0 | 0.01-2.85 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 21.1-22.0 | 0.01-2.72 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 22.1-23.0 | 0.01-2.60 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s | ||
| 23.1-24.0 | 0.01-2.50 | 60.00 | 200 | ± 5% | 89.00 % | ≤3s |