- Home
- About UE
- UE News
- Products
- Model
-
Open frame

-
Wall plug

-
Desktop

- Featured Products
-
UES120-SPAZ-OP

-
UES310D-SPAZ

-
PoE24

-
PoE90-560161

- R & D Center
- Join Us
- Contact Us
UES240E-SPCZ/UES240F-SPCZ
- Compliant with medical and telecommunications security certifications
- 2 MOPP isolation protection
- Leakage current ≤100μA
- Meets Level 7 efficacy
- Power consumption ≤ 0.15W
- 5V/9V/12V/15V/20V/28V/36V/48V输出,最高240W
- Working altitude 5000 meters
- Meets USB PD3.2, AVS, PPS, and QC3.0 fast charging protocols.
- USB port/fixed cable design
Product Features
| Input voltage | 80-264 volts AC | Working temp. | -10 ~ 40℃ |
| Input Current | 4.0A, under 80VAC input condition | Storage temperature | -20 ~ 80℃ |
| Altitude | 5000 meter | (I.e. | 5~90% RH, non-condensing |
| Standby power consumption | ≤0.15W | mean time between failures | At an ambient temperature of 25°C, the mean time between failures (MTBF) under maximum load is 10 hours (according to SR-332 standard). |
| weight | 650±15 grams | Mechanical specifications | 150(L) 73(W) 32.5(H) mm |
| Application places | Suitable for medical, information and information equipment power adapters | Safety standards | CB(IEC60601-1/IEC60601-1-11/IEC62368-1)、TuV-SUD/Mark(EN60601-1/EN60601-1-11)、UL(ANSI/AAMI ES60601-1/60601-1-11/CAN/CSA C22.0 NO.60601-1/UL62368-1)、RCM(AS/NZS 62368)、CE(EN62368)、CCC(GB4943.1)、FCC(FCC PART 15)、KC(K62368)、PSE(J62368) |
| model | Voltage(V) | Current (A) | Power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
UES240E-SPCZ UES240F-SPCZ
| 5.0 | 0.01-3.00 | 15 | 250 | ± 5% | Linear regulation: ±2% Load regulation: ±5%
| 82.0% | ≤3 seconds |
| 9.0 | 0.01-3.00 | 27 | 250 | ± 5% | 87.3% | ≤3 seconds | ||
| 12.0 | 0.01-3.00 | 36 | 250 | ± 5% | 88.3% | ≤3 seconds | ||
| 15.0 | 0.01-3.00 | 45 | 250 | ± 5% | 88.9% | ≤3 seconds | ||
| 20.0 | 0.01-5.00 | 100 | 300 | ± 5% | 89.5% | ≤3 seconds | ||
| 28.0 | 0.01-5.00 | 140 | 350 | ± 5% | 90.0% | ≤3 seconds | ||
| 36.0 | 0.01-5.00 | 180 | 350 | ± 5% | 91.0% | ≤3 seconds | ||
| 48.0 | 0.01-5.00 | 240 | 400 | ± 5% | 91.5% | ≤3 seconds |
Q1. What is the UES140AZ/UES140BZ-SPC?
A: The UES140AZ/UES140BZ-SPC is a desktop AC power supply adapter. It is a certified medical grade power supply and also serves as an information technology equipment power supply (ITE), making it a dual-certified switched power supply solution.
Q2. What are the key applications for this adapter?
A: As a certified medical power supply adapter and ITE adapter, it is designed for a wide range of devices. It is suitable for powering medical equipment and is also an ideal adapter tech medical power supply for charging ITE devices like laptops and peripherals, as it supports fast-charging protocols.
Q3. What output voltages does it provide?
A: It offers six fixed DC output voltages: 5V, 9V, 12V, 15 volt switching power supply (15V), 20V, and 28V. The maximum combined power across all outputs is 140W.
Q4. What safety features make it suitable for medical use?
A: The product meets strict medical safety requirements, including 2 MOPP (Means of Patient Protection) isolation and a low leakage current of ≤100µA, ensuring patient and operator safety when used as a medical device power supply.
Q5. What are its main electrical specifications and efficiency?
A: It has a wide universal AC input range of 80-264VAC. Its average efficiency ranges from 82% to 92%, depending on the output voltage, and it meets Energy Efficiency Level VI standards with a low standby power of ≤0.15W.
Q6. Which safety standards and certifications does it comply with?
A: It holds a comprehensive set of global certifications, making it suitable for worldwide markets. These include CB (IEC60601-1, IEC62368-1), TUV Mark (EN60601-1), UL (ANSI/AAMI ES60601-1, UL62368-1), CE, CCC, and FCC, among others.
Q7. How reliable is this power supply?
A: The product is designed for high reliability with a calculated Mean Time Between Failures (MTBF) of 100,000 hours at 25°C under maximum load (according to MIL-HDBK-217 standard).
Q8. What are its physical dimensions and operating conditions?
A: The adapter is compact, measuring 121mm (L) x 66mm (W) x 32mm (H), and weighs 340g. It operates in temperatures from 0°C ~ 40°C and at altitudes up to 5000 meters.
Q9. Does it support modern fast-charging protocols?
A: Yes. This switching power adapter is equipped with smart charging technology that supports multiple fast-charging protocols, including USB PD3.1, PD3.0, QC4.0+, and QC3.0.
Q10. Who is the manufacturer, and what is their background?
A: It is manufactured by UE Electronic, an experienced switching power supply manufacturer with a strong focus on medical and ITE power solutions, ensuring quality and compliance.
| Input voltage | 80-264 volts AC | Working temp. | -10 ~ 40℃ |
| Input Current | 4.0A, under 80VAC input condition | Storage temperature | -20 ~ 80℃ |
| Altitude | 5000 meter | (I.e. | 5~90% RH, non-condensing |
| Standby power consumption | ≤0.15W | mean time between failures | At an ambient temperature of 25°C, the mean time between failures (MTBF) under maximum load is 10 hours (according to SR-332 standard). |
| weight | 650±15 grams | Mechanical specifications | 150(L) 73(W) 32.5(H) mm |
| Application places | Suitable for medical, information and information equipment power adapters | Safety standards | CB(IEC60601-1/IEC60601-1-11/IEC62368-1)、TuV-SUD/Mark(EN60601-1/EN60601-1-11)、UL(ANSI/AAMI ES60601-1/60601-1-11/CAN/CSA C22.0 NO.60601-1/UL62368-1)、RCM(AS/NZS 62368)、CE(EN62368)、CCC(GB4943.1)、FCC(FCC PART 15)、KC(K62368)、PSE(J62368) |
| model | Voltage(V) | Current (A) | Power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
UES240E-SPCZ UES240F-SPCZ
| 5.0 | 0.01-3.00 | 15 | 250 | ± 5% | Linear regulation: ±2% Load regulation: ±5%
| 82.0% | ≤3 seconds |
| 9.0 | 0.01-3.00 | 27 | 250 | ± 5% | 87.3% | ≤3 seconds | ||
| 12.0 | 0.01-3.00 | 36 | 250 | ± 5% | 88.3% | ≤3 seconds | ||
| 15.0 | 0.01-3.00 | 45 | 250 | ± 5% | 88.9% | ≤3 seconds | ||
| 20.0 | 0.01-5.00 | 100 | 300 | ± 5% | 89.5% | ≤3 seconds | ||
| 28.0 | 0.01-5.00 | 140 | 350 | ± 5% | 90.0% | ≤3 seconds | ||
| 36.0 | 0.01-5.00 | 180 | 350 | ± 5% | 91.0% | ≤3 seconds | ||
| 48.0 | 0.01-5.00 | 240 | 400 | ± 5% | 91.5% | ≤3 seconds |
Product information
| Safety | CB, CE, cULus, FCC, TUV-Mark, UL |
|---|