UES90F-SPAZ

  • Meets medical safety certification
  • 2 MOPP isolation protection
  • Leakage current ≤ 100μA
  • Working altitude 5000 meters
  • Standby power consumption≤0.15W
  • Peak load: 168W at rated input voltage
  • Working altitude 5000 meters
  • 11VTo 54VOutputUp to 90W
Product Features
Input voltage90-264VACWorking temp.-10 ~ 40℃ 
Input Current2.2A, at 100VAC Storage temperature-40 ~ 70℃ 
Output voltage range11-54V (I.e.10~90% RH, non-condensing
mean time between failuresAt an ambient temperature of 25°C, the mean time between failures (MTBF) under maximum load is 100,000 hours (according to Telcordia_SR-332 standard). 
weight300gMechanical specifications121(L)  66(W)  32(H)mm 
Application placesSuitable for medical equipment power adapterSafety standards
  • CB( IEC60601-1/IEC62368-1)
  • UL(ANSI/AAMI ES60601-1/CAN/CSA C22.2 NO.60601-1 /UL62368-1)
  • TUV Mark(EN60601-1 )
  • TUV-SUD/GS(EN62368-1)
  • CE(EN62368)
  • CCC(GB4943.1)
 
modelVoltageCurrentWatts

Ripple and noise

Voltage tolerance

Linear and load regulationAverage efficiencyStart delay time
UES90F-XXXYYYSPAZ11.0 0.01-7.0077.00W150mVpk-pk± 5%Linear adjustment rate: ± 1%
Load: ± 5%


88.00 %≤3s
12.0 0.01-7.0084.00W150mVpk-pk± 5%88.00 %≤3s
15.0 0.01-6.0090.00W180mVpk-pk± 5%88.00 %≤3s
18.0 0.01-5.0090.00W200mVpk-pk± 5%88.00 %≤3s
19.0 0.01-4.7490.00W200mVpk-pk± 5%88.00 %≤3s
22.0 0.01-4.0990.00W200mVpk-pk± 5%88.00 %≤3s
24.0 0.01-3.7590.00W200mVpk-pk± 5%88.00 %≤3s
26.0 0.01-3.4690.00W200mVpk-pk± 5%88.00 %≤3s
30.0 0.01-3.0090.00W200mVpk-pk± 5%88.00 %≤3s
33.0 0.01-2.7390.00W200mVpk-pk± 5%88.00 %≤3s
36.0 0.01-2.5090.00W200mVpk-pk± 5%88.00 %≤3s
39.0 0.01-2.3190.00W200mVpk-pk± 5%88.00 %≤3s
43.0 0.01-2.0990.00W300mVpk-pk± 5%88.00 %≤3s
46.0 0.01-1.9590.00W300mVpk-pk± 5%88.00 %≤3s
48.0 0.01-1.8890.00W300mVpk-pk± 5%88.00 %≤3s
52.0 0.01-1.7390.00W300mVpk-pk± 5%88.00 %≤3s
54.0 0.01-1.6790.00W300mVpk-pk± 5%88.00 %≤3s
Input voltage90-264VACWorking temp.-10 ~ 40℃ 
Input Current2.2A, at 100VAC Storage temperature-40 ~ 70℃ 
Output voltage range11-54V (I.e.10~90% RH, non-condensing
mean time between failuresAt an ambient temperature of 25°C, the mean time between failures (MTBF) under maximum load is 100,000 hours (according to Telcordia_SR-332 standard). 
weight300gMechanical specifications121(L)  66(W)  32(H)mm 
Application placesSuitable for medical equipment power adapterSafety standards
  • CB( IEC60601-1/IEC62368-1)
  • UL(ANSI/AAMI ES60601-1/CAN/CSA C22.2 NO.60601-1 /UL62368-1)
  • TUV Mark(EN60601-1 )
  • TUV-SUD/GS(EN62368-1)
  • CE(EN62368)
  • CCC(GB4943.1)
 
modelVoltageCurrentWatts

Ripple and noise

Voltage tolerance

Linear and load regulationAverage efficiencyStart delay time
UES90F-XXXYYYSPAZ11.0 0.01-7.0077.00W150mVpk-pk± 5%Linear adjustment rate: ± 1%
Load: ± 5%


88.00 %≤3s
12.0 0.01-7.0084.00W150mVpk-pk± 5%88.00 %≤3s
15.0 0.01-6.0090.00W180mVpk-pk± 5%88.00 %≤3s
18.0 0.01-5.0090.00W200mVpk-pk± 5%88.00 %≤3s
19.0 0.01-4.7490.00W200mVpk-pk± 5%88.00 %≤3s
22.0 0.01-4.0990.00W200mVpk-pk± 5%88.00 %≤3s
24.0 0.01-3.7590.00W200mVpk-pk± 5%88.00 %≤3s
26.0 0.01-3.4690.00W200mVpk-pk± 5%88.00 %≤3s
30.0 0.01-3.0090.00W200mVpk-pk± 5%88.00 %≤3s
33.0 0.01-2.7390.00W200mVpk-pk± 5%88.00 %≤3s
36.0 0.01-2.5090.00W200mVpk-pk± 5%88.00 %≤3s
39.0 0.01-2.3190.00W200mVpk-pk± 5%88.00 %≤3s
43.0 0.01-2.0990.00W300mVpk-pk± 5%88.00 %≤3s
46.0 0.01-1.9590.00W300mVpk-pk± 5%88.00 %≤3s
48.0 0.01-1.8890.00W300mVpk-pk± 5%88.00 %≤3s
52.0 0.01-1.7390.00W300mVpk-pk± 5%88.00 %≤3s
54.0 0.01-1.6790.00W300mVpk-pk± 5%88.00 %≤3s

Additional information

Related Products
model
Output Voltage
Output Current
power
Application industry
Data sheet
Compared
UES90-SPA-OP1 12V/15V/18V/24V/36V/48V 0.01-7.0A 90W Medical/I.T.E.
UES90C-SPAZ 11-54V 0.01-7.00A 90W Communications/Medical Industry
UES90F-SPAZ 11-54V 0.01-7.00A 90W Medical
UES100DZ-SPA 12-15V/19-24V 0.01-7.50A 100W Medical
UES100LCP2-SPC 5V/9V/12V/15V/20V 0.01-5.00A 100W Medical/I.T.E.
UES100B/UES100C-SPCZ 5V/9V/12V/15V/20V 0.01-5.00A 100W Medical/I.T.E.