UES90C-SPAZ
- Comply with communication and medical safety certification
- 2 MOPP isolation protection
- PF>0.90@230VAC full load
- Leakage current ≤ 100μA
- Working altitude 5000 meters
- Standby power consumption≤0.21W
- Working altitude 5000 meters
- 11VTo 54VOutput, highest12W
Product Features
| Input voltage | 90-264VAC | Working temp. | 0 ~ 40 ℃ | |
| Input Current | 1.5A, at 80VAC | Storage temperature | -20 ~ 60℃ | |
| Output voltage range | 11-54V | (I.e. | 10~90% RH, non-condensing | |
| mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard) | |||
| weight | 300g | Mechanical specifications | 137(L) 62(W) 32(H)mm | |
| Application places | Suitable for medical and information equipment power adapters | Safety standards |
| |
| model | Voltage | Current | Watts | Ripple and noise | Voltage tolerance | Linear and load regulation | Average efficiency | Start delay time |
| UES90C-XXXYYYSPAZ | 11.0 | 0.01-7.00 | 77.00W | 150mVpk-pk | ± 5% | Linear adjustment rate: ± 1% Load: ± 5% | 88.00% | ≤3s |
| 12.0 | 0.01-7.00 | 84.00W | 150mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 15.0 | 0.01-6.00 | 90.00W | 180mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 17.0 | 0.01-5.29 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 19.0 | 0.01-4.74 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 22.0 | 0.01-4.09 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 24.0 | 0.01-3.75 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 26.0 | 0.01-3.46 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 30.0 | 0.01-3.00 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 33.0 | 0.01-2.73 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 36.0 | 0.01-2.50 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 39.0 | 0.01-2.31 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 43.0 | 0.01-2.09 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 46.0 | 0.01-1.95 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 48.0 | 0.01-1.88 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 52.0 | 0.01-1.73 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 54.0 | 0.01-1.67 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s |
| Input voltage | 90-264VAC | Working temp. | 0 ~ 40 ℃ | |
| Input Current | 1.5A, at 80VAC | Storage temperature | -20 ~ 60℃ | |
| Output voltage range | 11-54V | (I.e. | 10~90% RH, non-condensing | |
| mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard) | |||
| weight | 300g | Mechanical specifications | 137(L) 62(W) 32(H)mm | |
| Application places | Suitable for medical and information equipment power adapters | Safety standards |
| |
| model | Voltage | Current | Watts | Ripple and noise | Voltage tolerance | Linear and load regulation | Average efficiency | Start delay time |
| UES90C-XXXYYYSPAZ | 11.0 | 0.01-7.00 | 77.00W | 150mVpk-pk | ± 5% | Linear adjustment rate: ± 1% Load: ± 5% | 88.00% | ≤3s |
| 12.0 | 0.01-7.00 | 84.00W | 150mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 15.0 | 0.01-6.00 | 90.00W | 180mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 17.0 | 0.01-5.29 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 19.0 | 0.01-4.74 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 22.0 | 0.01-4.09 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 24.0 | 0.01-3.75 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 26.0 | 0.01-3.46 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 30.0 | 0.01-3.00 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 33.0 | 0.01-2.73 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 36.0 | 0.01-2.50 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 39.0 | 0.01-2.31 | 90.00W | 200mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 43.0 | 0.01-2.09 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 46.0 | 0.01-1.95 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 48.0 | 0.01-1.88 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 52.0 | 0.01-1.73 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s | ||
| 54.0 | 0.01-1.67 | 90.00W | 300mVpk-pk | ± 5% | 88.00% | ≤3s |
Additional information
Compare—
Related Products
model
Output Voltage
Output Current
power
Application industry
Data sheet
Compared