- Home
- About UE
- UE News
- Products
- Model
-
Open frame

-
Wall plug

-
Desktop

- Featured Products
-
UES120-SPAZ-OP

-
UES310D-SPAZ

-
PoE24

-
PoE90-560161

- R & D Center
- Join Us
- Contact Us
UES90-SPA-OP1
- Compliant with communications and medical safety certifications
- 2 MOPP isolation protection
- Leakage current ≤ 100
- Energy Efficiency level VI
- Standby power consumption≤0.21W
- Working altitude 5000 meters
- Dip switch control output
- Convection cool
Product Features
| Input voltage | 90-264VAC (90-115VAC reference derating curve) | Working temp. | -30~70℃ (45-70℃ reference derating curve) | ||||||||
| Input Current | 1.5A, under 100VAC input condition | Storage temperature | -40 ~ 80℃ | ||||||||
| Output voltage range | ± 5% | Working humidity | 10 ~ 90% | ||||||||
| Standby power consumption | 0.21W | mean time between failures | >100,000hrs MIL-HDBK-217, at 25℃ ambient temperature. | ||||||||
| weight | About 190g | Mechanical specifications | 101.6(L) 50.8(W) 29.0(H)mm | ||||||||
| Application places | Suitable for medical and ITE equipment power adapters | Safety standards | 符合CB(IEC60601-1)、TUV-SUD Mark(EN60601-1)、NRTL(ANSI/AAMI ES60601-1,CAN/CSA-C22.2NO.60601-1) | ||||||||
| model | Voltage (V) | Current (A) | power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES90-XXXYYYSPA-OP1 | 12.00 | 0.01-7.00 | 84.0 | 100 | ± 5% | Linear adjustment rate: ± 1% Load: ± 5% | 89% | ≤3s |
| 15.00 | 0.01-6.00 | 90.0 | 120 | 89% | ≤3s | |||
| 18.00 | 0.01-5.00 | 90.0 | 150 | 89% | ≤3s | |||
| 24.00 | 0.01-3.75 | 90.0 | 150 | 90% | ≤3s | |||
| 36.00 | 0.01-2.50 | 90.0 | 150 | 90% | ≤3s | |||
| 48.00 | 0.01-1.87 | 90.0 | 150 | 90% | ≤3s |
| Input voltage | 90-264VAC (90-115VAC reference derating curve) | Working temp. | -30~70℃ (45-70℃ reference derating curve) | ||||||||
| Input Current | 1.5A, under 100VAC input condition | Storage temperature | -40 ~ 80℃ | ||||||||
| Output voltage range | ± 5% | Working humidity | 10 ~ 90% | ||||||||
| Standby power consumption | 0.21W | mean time between failures | >100,000hrs MIL-HDBK-217, at 25℃ ambient temperature. | ||||||||
| weight | About 190g | Mechanical specifications | 101.6(L) 50.8(W) 29.0(H)mm | ||||||||
| Application places | Suitable for medical and ITE equipment power adapters | Safety standards | 符合CB(IEC60601-1)、TUV-SUD Mark(EN60601-1)、NRTL(ANSI/AAMI ES60601-1,CAN/CSA-C22.2NO.60601-1) | ||||||||
| model | Voltage (V) | Current (A) | power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES90-XXXYYYSPA-OP1 | 12.00 | 0.01-7.00 | 84.0 | 100 | ± 5% | Linear adjustment rate: ± 1% Load: ± 5% | 89% | ≤3s |
| 15.00 | 0.01-6.00 | 90.0 | 120 | 89% | ≤3s | |||
| 18.00 | 0.01-5.00 | 90.0 | 150 | 89% | ≤3s | |||
| 24.00 | 0.01-3.75 | 90.0 | 150 | 90% | ≤3s | |||
| 36.00 | 0.01-2.50 | 90.0 | 150 | 90% | ≤3s | |||
| 48.00 | 0.01-1.87 | 90.0 | 150 | 90% | ≤3s |
Additional information
Compare—
Related Products
model
Output Voltage
Output Current
power
Application industry
Data sheet
Compared