- Home
- About UE
- UE News
- Products
- Model
-
Open frame
-
Wall plug
-
Desktop
- Featured Products
-
UES15LZ-SPAZ/UES15LZ1-SPAZ
-
UE05LCP-SPA
-
UES240DZ-XXXYYYSPA
-
UES180DZ-SPA
-
UES120DZ-SPA
- Featured Products
-
UEP68Y322XXX
-
UEP35Y322XXX
-
UES60D1-200300SPC
Warning: foreach () argument must be of type array | object, bool given in /www/wwwroot/8.210.154.105/fuhua.heniw.com/wp-content/plugins/custommainmenu/custommainmenu.php on line 149
Warning: foreach () argument must be of type array | object, bool given in /www/wwwroot/8.210.154.105/fuhua.heniw.com/wp-content/plugins/custommainmenu/custommainmenu.php on line 160
Warning: foreach () argument must be of type array | object, bool given in /www/wwwroot/8.210.154.105/fuhua.heniw.com/wp-content/plugins/custommainmenu/custommainmenu.php on line 149
Warning: foreach () argument must be of type array | object, bool given in /www/wwwroot/8.210.154.105/fuhua.heniw.com/wp-content/plugins/custommainmenu/custommainmenu.php on line 160
Warning: foreach () argument must be of type array | object, bool given in /www/wwwroot/8.210.154.105/fuhua.heniw.com/wp-content/plugins/custommainmenu/custommainmenu.php on line 149
Warning: foreach () argument must be of type array | object, bool given in /www/wwwroot/8.210.154.105/fuhua.heniw.com/wp-content/plugins/custommainmenu/custommainmenu.php on line 160 - R & D Center
- Join Us
- Contact Us
UES90-XXXYYYSPA-OP1
- Compliant with communications and medical safety certifications
- 2 MOPP isolation protection
- Leakage current ≤ 100
- Energy Efficiency level VI
- Standby power consumption≤0.21W
- Working altitude 5000 meters
- Dip switch control output
- Windless design features, natural air cooling
Product Features
Input voltage | 90-264VAC (90-115VAC reference derating curve) | Operating temperature | -30~70℃ (45-70℃ reference derating curve) | ||||||||
Input Current | 1.5A, under 100VAC input condition | Storage temperature | -40 ~ 80℃ | ||||||||
Output voltage range | ± 5% | Working humidity | 10 ~ 90% | ||||||||
Standby power consumption | 0.21W | mean time between failures | >100,000hrs MIL-HDBK-217, at 25℃ ambient temperature. | ||||||||
weight | About 190g | Mechanical specifications | 101.6(L) 50.8(W) 29.0(H)mm | ||||||||
Application places | Suitable for medical and ITE equipment power adapters | Safety standards | 符合CB(IEC60601-1)、TUV-SUD Mark(EN60601-1)、NRTL(ANSI/AAMI ES60601-1,CAN/CSA-C22.2NO.60601-1) | ||||||||
model | Voltage (V) | Current (A) | power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
UES90-XXXYYYSPA-OP1 | 12.00 | 0.01-7.00 | 84.0 | 100 | ± 5% | Linear adjustment rate: ± 1% Hello Elena: ± 5% | 89% | ≤3s |
15.00 | 0.01-6.00 | 90.0 | 120 | 89% | ≤3s | |||
18.00 | 0.01-5.00 | 90.0 | 150 | 89% | ≤3s | |||
24.00 | 0.01-3.75 | 90.0 | 150 | 90% | ≤3s | |||
36.00 | 0.01-2.50 | 90.0 | 150 | 90% | ≤3s | |||
48.00 | 0.01-1.87 | 90.0 | 150 | 90% | ≤3s |