- Home
- About UE
- UE News
- Products
- Model
-
Open frame

-
Wall plug

-
Desktop

- Featured Products
-
UES120-SPAZ-OP

-
UES310D-SPAZ

-
PoE24

-
PoE90-560161

- R & D Center
- Join Us
- Contact Us
UES36LCP1-SPA
- Comply with communication and medical safety certification
- 2 MOPP isolation protection
- Leakage current ≤ 100μA
- DOE Efficiercy Level VI
- CoC V5 Tier2(2016)
- Standby power consumption≤0.075W
- 5V to 48V output, up to 36W
- Working altitude 5000 meters
- Comes with a variety of interchangeable AC plugs
Product Features
| Input voltage | 80-264VAC | Working temp. | 0 ~ 45 ℃ |
| Input Current | 1.0A, under 80VAC input conditions | Storage temperature | -20 ~ 60℃ |
| Output voltage range | ± 5% | (I.e. | 10~90% RH, non-condensing |
| Standby power consumption | 0.075W | mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard) |
| weight | 210g | Mechanical specifications | 90.5(L) 33.5(W) 58.5(H)mm |
| Application places | Suitable for medical, information and information equipment power adapters | Safety standards | CB( IEC60601-1/IEC60601-1-11/IEC62368-1)、UL(ANSI/AAMI ES60601-1/60601-1-11/CAN/CSA-C22.2 NO. 60601-1/UL62368)、TüV Rheinland/Mark(EN60601-1/EN60601-1-11)、TüV Rheinland/GS( EN62368-1)、CE(EN62368)、CCC (GB4943.1)、PSE(J62368)、KC( K60950-1)、RCM(AS/NES62368)、FCC(FCC PART 15)、PSB(IEC60950-1)、BIS(IEC60950-1) |
model | Voltage | Current | Rated wattage | Ripple | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES36LCP1-XXXYYYSPA | 5.0 | 0.01-6.00 | 30 watts | 200mVpk-pk | ±5% | Linear adjustment rate: ±1% Load: ±5% | 85.00% | ≤3 seconds |
| 5.1 | 0.01-5.00 | 30 watts | 200mVpk-pk | ±5% | 88.30% | ≤3 seconds | ||
| 7.5-14.0 | 0.01-4.00 | 36 watts | 200mVpk-pk | ±5% | 88.30% | ≤3 seconds | ||
| 14.1-21.0 | 0.01-2.40 | 36 watts | 200mVpk-pk | ±5% | 88.30% | ≤3 seconds | ||
| 21.1-30.3 | 0.01-1.63 | 36 watts | 300mVpk-pk | ±5% | 88.30% | ≤3 seconds | ||
| 30.1-48.0 | 0.01-1.16 | 36 watts | 300mVpk-pk | ±5% | 88.30% | ≤3 seconds |
| Input voltage | 80-264VAC | Working temp. | 0 ~ 45 ℃ |
| Input Current | 1.0A, under 80VAC input conditions | Storage temperature | -20 ~ 60℃ |
| Output voltage range | ± 5% | (I.e. | 10~90% RH, non-condensing |
| Standby power consumption | 0.075W | mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard) |
| weight | 210g | Mechanical specifications | 90.5(L) 33.5(W) 58.5(H)mm |
| Application places | Suitable for medical, information and information equipment power adapters | Safety standards | CB( IEC60601-1/IEC60601-1-11/IEC62368-1)、UL(ANSI/AAMI ES60601-1/60601-1-11/CAN/CSA-C22.2 NO. 60601-1/UL62368)、TüV Rheinland/Mark(EN60601-1/EN60601-1-11)、TüV Rheinland/GS( EN62368-1)、CE(EN62368)、CCC (GB4943.1)、PSE(J62368)、KC( K60950-1)、RCM(AS/NES62368)、FCC(FCC PART 15)、PSB(IEC60950-1)、BIS(IEC60950-1) |
model | Voltage | Current | Rated wattage | Ripple | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES36LCP1-XXXYYYSPA | 5.0 | 0.01-6.00 | 30 watts | 200mVpk-pk | ±5% | Linear adjustment rate: ±1% Load: ±5% | 85.00% | ≤3 seconds |
| 5.1 | 0.01-5.00 | 30 watts | 200mVpk-pk | ±5% | 88.30% | ≤3 seconds | ||
| 7.5-14.0 | 0.01-4.00 | 36 watts | 200mVpk-pk | ±5% | 88.30% | ≤3 seconds | ||
| 14.1-21.0 | 0.01-2.40 | 36 watts | 200mVpk-pk | ±5% | 88.30% | ≤3 seconds | ||
| 21.1-30.3 | 0.01-1.63 | 36 watts | 300mVpk-pk | ±5% | 88.30% | ≤3 seconds | ||
| 30.1-48.0 | 0.01-1.16 | 36 watts | 300mVpk-pk | ±5% | 88.30% | ≤3 seconds |