UES24LCP-SPA
The UES24LCP-SPA series from UE Electronic is a compact and reliable power solution featuring a universal AC plug adapter design. It supports stable output for medical switched mode power supplies, ITE switching power supply applications and devices requiring a battery charger connector plug. This switching power adapter is engineered with a durable AC plug switch, enabling flexible interchange power switch configurations. With 30-year+ of power supply expertise, a complete EMC laboratory, and comprehensive test equipment, UE Electronic ensures consistent quality and safety for global device manufacturers.
- medical andITEsafety certificate
- 2 MOPP isolation protection
- touch current ≤ 100
- CoC V5 Tier 2
- DOE Level XNUMX Energy Efficiency
- Standby power consumption≤0.075W
- 6.1V-52V output, up to 24W
- Working altitude 5000 meters
- Equipped with various interchangeable stylesAC pin
- Covers short circuit protection, overvoltage protection, and overload protection;
Product Features
| Input voltage | 90-264VAC | Working temp. | 0 ~ 45 ℃ |
| Input Current | 0.5A | Storage temperature | -20℃ to 60℃ |
| Working altitude | 5000m | Working humidity | 10~90% RH, non-condensing |
| Standby power consumption | ≤0.075W | mean time between failures | >100,000hrs MIL-HDBK-217, at 25℃ ambient temperature. |
| weight | 170g | Mechanical specifications | 88.0(L) 30.0(W) 57.0(H)mm |
| Application places | Suitable for medical and information equipment power adapters | Safety standards | CB(IEC60601-1/IEC60950-1/IEC62368-1)、UL(ANSI / AAMI ES60601-1/CAN / CSA-C22.2 NO.60601-1/CAN/CSA C22.2 NO.60950-1/UL60950-1/UL62368-1)、TuV Rheinland-Mark(EN60601-1)、TüV Rheinland-GS( EN62368-1)、CCC(GB4943.1)、PSE(J62368/J60950)、RCM(AS/NZS62368.1)、CE(EN62368)、FCC(FCC PART 15)、KC(K60950-1) |
|
model | Voltage | Current | Ripple | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
UES24LCP-XXXYYYSPA UES24LCP-XXXYYYSPA-OP
| 6.1-7.0 | 0.01-3.00 | 120 | ± 5% |
Linear adjustment rate:±1% Load:±5%
| 86.20% | ≤3s |
7.1-8.0 | 0.01-2.62 | 120 | ± 5% | 86.20% | ≤3s | ||
8.1-9.0 | 0.01-2.33 | 150 | ± 5% | 86.20% | ≤3s | ||
9.1-10.0 | 0.01-2.10 | 150 | ± 5% | 86.20% | ≤3s | ||
10.1-11.0 | 0.01-2.18 | 150 | ± 5% | 87.00% | ≤3s | ||
11.1-12.0 | 0.01-2.00 | 150 | ± 5% | 87.00% | ≤3s | ||
12.1-13.0 | 0.01-1.84 | 200 | ± 5% | 87.00% | ≤3s | ||
13.1-14.0 | 0.01-1.71 | 200 | ± 5% | 87.00% | ≤3s | ||
14.1-15.0 | 0.01-1.60 | 200 | ± 5% | 87.00% | ≤3s | ||
15.1-16.0 | 0.01-1.50 | 200 | ± 5% | 87.00% | ≤3s | ||
16.1-17.0 | 0.01-1.41 | 200 | ± 5% | 87.00% | ≤3s | ||
17.1-18.0 | 0.01-1.33 | 200 | ± 5% | 87.00% | ≤3s | ||
18.1-19.0 | 0.01-1.26 | 200 | ± 5% | 87.00% | ≤3s | ||
19.1-20.0 | 0.01-1.20 | 240 | ± 5% | 87.00% | ≤3s | ||
20.1-21.0 | 0.01-1.14 | 240 | ± 5% | 87.00% | ≤3s | ||
21.1-22.0 | 0.01-1.09 | 240 | ± 5% | 87.00% | ≤3s | ||
22.0-23.0 | 0.01-1.04 | 240 | ± 5% | 87.00% | ≤3s | ||
23.1-24.0 | 0.01-1.00 | 240 | ± 5% | 87.00% | ≤3s | ||
45.1-46.0 | 0.01-0.52 | 300 | ± 5% | 87.00% | ≤3s | ||
46.1-47.0 | 0.01-0.50 | 300 | ± 5% | 87.00% | ≤3s | ||
47.1-48.0 | 0.01-0.49 | 300 | ± 5% | 87.00% | ≤3s | ||
48.1-49.0 | 0.01-0.48 | 300 | ± 5% | 87.00% | ≤3s | ||
49.1-50.0 | 0.01-0.47 | 300 | ± 5% | 87.00% | ≤3s | ||
50.1-51.0 | 0.01-0.46 | 300 | ± 5% | 87.00% | ≤3s | ||
51.1-52.0 | 0.01-0.51 | 300 | ± 5% | 87.00% | ≤3s |
Comprehensive Application Coverage
The UES24LCP-SPA series delivers stable performance for devices using a universal AC plug adapter, meeting requirements for medical switched mode power supplies, ITE switching power supply and general power conversion needs. Supported by UE Electronic’s advanced EMC laboratory and full-range verification systems, the product ensures dependable long-term operation.
Medical Applications
The design is suitable for equipment utilizing medical switched mode power supplies, providing reliable power input with compatible battery charger connector plug configurations needed in clinical or monitoring devices.
Communication Applications
For communication devices requiring ITE switching power supply and flexible AC plug switch or switch plug solutions, the UES24LCP-SPA provides stable output and consistent electromagnetic performance.
General Use
The product supports applications in consumer electronics, portable instruments, and equipment integrating switch with plug combo or interchange power switch designs, ensuring high reliability backed by UE Electronic’s 30-year+ manufacturing capability.
Q1. What type of power supply is the UES24LCP-SPA?
A: The UES24LCP-SPA is a 24W wall-mount type, medical-grade switching power adapter. It is specifically designed and certified for use in both medical equipment and Information Technology Equipment (ITE), making it a highly reliable universal AC plug adapter for global applications.
Q2. What are its key applications?
A: Its primary application is as a medical switched mode power supply for devices like portable patient monitors, ventilators, and diagnostic tools. It also serves as a compliant ITE switching power supply for communication devices, industrial controls, and laboratory equipment.
Q3. What is the significance of the interchangeable AC plug?
A: The product features a key innovation: it comes with multiple interchangeable power switch plugs (e.g., US, EU, UK, AU types). This allows the same power adapter switch unit to be easily reconfigured for different regional sockets, eliminating the need for separate models for international markets and simplifying logistics.
Q4. What are the key electrical specifications?
A: It has a wide universal AC input range (90-264VAC) and a configurable DC output from 6.1V up to 52V, with a maximum power of 24W. Its standby power consumption is very low, at ≤0.075W.
Q5. What safety features make it suitable for medical use?
A: It incorporates critical medical safety standards, including 2 MOPP (Means of Patient Protection) isolation, which ensures high protection against electric shock. It also features very low leakage/touch current (as low as ≤100μA for certain outputs), which is crucial for patient-connected devices.
Q6. What safety and regulatory certifications does it hold?
A: The adapter holds comprehensive global certifications. For medical use, it complies with IEC60601-1, ANSI/AAMI ES60601-1, and EN60601-1. For ITE applications, it meets standards like IEC62368-1 and UL60950-1.
Q7. What are its physical dimensions and environmental ratings?
A: The unit is compact, measuring approximately 88mm (L) x 30mm (W) x 57mm (H). It is designed to operate reliably in a range of conditions, from 0°C to 45°C and at altitudes up to 5000 meters.
Q8. Does it offer protection for connected devices?
A: Yes, it includes comprehensive built-in protections such as output short-circuit, overload, and over-voltage protection to safeguard both the power supply itself and the valuable equipment it powers.
Q9. What connector options are available for the output?
A: While the standard DC output cable and battery charger connector plug can be customized, it is important to confirm the exact connector type (e.g., barrel jack size) for your specific device model before integration.
Q10. Can it be used as a direct replacement for a standard AC power socket?
A: No. This is not a simple switch with plug combo for wall outlets. It is a regulated external AC plug switch power adapter that converts high-voltage AC mains power to safe, low voltage DC power required by sensitive medical and electronic devices.
| Input voltage | 90-264VAC | Working temp. | 0 ~ 45 ℃ |
| Input Current | 0.5A | Storage temperature | -20℃ to 60℃ |
| Working altitude | 5000m | Working humidity | 10~90% RH, non-condensing |
| Standby power consumption | ≤0.075W | mean time between failures | >100,000hrs MIL-HDBK-217, at 25℃ ambient temperature. |
| weight | 170g | Mechanical specifications | 88.0(L) 30.0(W) 57.0(H)mm |
| Application places | Suitable for medical and information equipment power adapters | Safety standards | CB(IEC60601-1/IEC60950-1/IEC62368-1)、UL(ANSI / AAMI ES60601-1/CAN / CSA-C22.2 NO.60601-1/CAN/CSA C22.2 NO.60950-1/UL60950-1/UL62368-1)、TuV Rheinland-Mark(EN60601-1)、TüV Rheinland-GS( EN62368-1)、CCC(GB4943.1)、PSE(J62368/J60950)、RCM(AS/NZS62368.1)、CE(EN62368)、FCC(FCC PART 15)、KC(K60950-1) |
|
model | Voltage | Current | Ripple | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
UES24LCP-XXXYYYSPA UES24LCP-XXXYYYSPA-OP
| 6.1-7.0 | 0.01-3.00 | 120 | ± 5% |
Linear adjustment rate:±1% Load:±5%
| 86.20% | ≤3s |
7.1-8.0 | 0.01-2.62 | 120 | ± 5% | 86.20% | ≤3s | ||
8.1-9.0 | 0.01-2.33 | 150 | ± 5% | 86.20% | ≤3s | ||
9.1-10.0 | 0.01-2.10 | 150 | ± 5% | 86.20% | ≤3s | ||
10.1-11.0 | 0.01-2.18 | 150 | ± 5% | 87.00% | ≤3s | ||
11.1-12.0 | 0.01-2.00 | 150 | ± 5% | 87.00% | ≤3s | ||
12.1-13.0 | 0.01-1.84 | 200 | ± 5% | 87.00% | ≤3s | ||
13.1-14.0 | 0.01-1.71 | 200 | ± 5% | 87.00% | ≤3s | ||
14.1-15.0 | 0.01-1.60 | 200 | ± 5% | 87.00% | ≤3s | ||
15.1-16.0 | 0.01-1.50 | 200 | ± 5% | 87.00% | ≤3s | ||
16.1-17.0 | 0.01-1.41 | 200 | ± 5% | 87.00% | ≤3s | ||
17.1-18.0 | 0.01-1.33 | 200 | ± 5% | 87.00% | ≤3s | ||
18.1-19.0 | 0.01-1.26 | 200 | ± 5% | 87.00% | ≤3s | ||
19.1-20.0 | 0.01-1.20 | 240 | ± 5% | 87.00% | ≤3s | ||
20.1-21.0 | 0.01-1.14 | 240 | ± 5% | 87.00% | ≤3s | ||
21.1-22.0 | 0.01-1.09 | 240 | ± 5% | 87.00% | ≤3s | ||
22.0-23.0 | 0.01-1.04 | 240 | ± 5% | 87.00% | ≤3s | ||
23.1-24.0 | 0.01-1.00 | 240 | ± 5% | 87.00% | ≤3s | ||
45.1-46.0 | 0.01-0.52 | 300 | ± 5% | 87.00% | ≤3s | ||
46.1-47.0 | 0.01-0.50 | 300 | ± 5% | 87.00% | ≤3s | ||
47.1-48.0 | 0.01-0.49 | 300 | ± 5% | 87.00% | ≤3s | ||
48.1-49.0 | 0.01-0.48 | 300 | ± 5% | 87.00% | ≤3s | ||
49.1-50.0 | 0.01-0.47 | 300 | ± 5% | 87.00% | ≤3s | ||
50.1-51.0 | 0.01-0.46 | 300 | ± 5% | 87.00% | ≤3s | ||
51.1-52.0 | 0.01-0.51 | 300 | ± 5% | 87.00% | ≤3s |