UES24DZ-SPA

  • Comply with communication and medical safety certification
  • 2 MOPP isolation protection
  • Energy Efficiency level VI
  • Leakage current ≤ 100μA
  • Standby power consumption≤0.075W
  • Working altitude 5000 meters
  •  
Product Features
Input voltage80-264VACWorking temp.0 ~ 45 ℃
Input Current800mA Storage temperature-20 ~ 60℃
Output voltage range± 5%(I.e.Under non-concentrated conditions, humidity 10%~90%
Standby power consumption0.075W MAXmean time between failuresAt an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard)
weight132gMechanical specifications89.0(L)  49.0(W)  29.0(H)mm
Application placesSuitable for medical and communication power adaptersSafety standardsCB(IEC60601-1-11,IEC62368-1),TUV Rheinland/mark(EN60601-1),UL(ANSI/AAMI ES 60601-1 CAN/CSAC22.2NO.60601-1)
model

Voltage

(V)

Current

(A)

power

(W)

Ripple and noise

(mVpk-pk)

Voltage toleranceLinear and load regulation

Average efficiency (%) Min

Start delay time
UES24DZ-120YYYYPA12.00.1-2.024150± 5%Linear adjustment rate: ± 1%
Load: ± 5%
86.8≤3s
Input voltage80-264VACWorking temp.0 ~ 45 ℃
Input Current800mA Storage temperature-20 ~ 60℃
Output voltage range± 5%(I.e.Under non-concentrated conditions, humidity 10%~90%
Standby power consumption0.075W MAXmean time between failuresAt an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard)
weight132gMechanical specifications89.0(L)  49.0(W)  29.0(H)mm
Application placesSuitable for medical and communication power adaptersSafety standardsCB(IEC60601-1-11,IEC62368-1),TUV Rheinland/mark(EN60601-1),UL(ANSI/AAMI ES 60601-1 CAN/CSAC22.2NO.60601-1)
model

Voltage

(V)

Current

(A)

power

(W)

Ripple and noise

(mVpk-pk)

Voltage toleranceLinear and load regulation

Average efficiency (%) Min

Start delay time
UES24DZ-120YYYYPA12.00.1-2.024150± 5%Linear adjustment rate: ± 1%
Load: ± 5%
86.8≤3s

Product information

Related Products
model
Output Voltage
Output Current
power
Application industry
Data sheet
Compared
UES10LZ1-SPA/UES10LZ2-SPA 5V was added to 0.01-2.0A 10W Medical/I.T.E.
UES10WCP-SPC-M2 5V was added to 0.10-1.00A 10W I.T.E.
UES12L1-SPAZ 12V was added to 0.01-1.00A 12W I.T.E.
UES12-120100SPA1-OP 12V was added to 0.01-1.00A 12W I.T.E.
UES12WU2-SPA 12V was added to 0.01-1.00A 12W I.T.E.
PoE12WC-480025 48V was added to 0.01-0.25A 12W PoE
UES12D1-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UE12LC2-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UES12LCP-SPA/UES12LCP-SPC 4-24V was added to 0.01-2.0A 12W Medical/I.T.E.
UES12LCP2-SPA 4-24V was added to 0.01-2.00A 12W Medical/I.T.E.
UE12LC1-SPAZ 12V was added to 0.01-1.00A 12W I.T.E.
UES12LD4-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UES12LZ11-SPA 12V was added to 0.01-1.00A 12W Medical/I.T.E.
UES12WV1-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UES12LZ5-SPA 15V / 19V was added to 0.01-0.8A 12W Household/I.T.E.
UE12-120100SPA2-OP 12V was added to 0.01-1.00A 12W I.T.E.
UES12LCP1-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UES15LZ-SPAZ/UES15LZ1-SPAZ 5V was added to 0.01-3.0A 15W Medical/I.T.E.
UES15-SPA2-OP 12V was added to 0.01-1.25A 15W I.T.E.
UE15-150100SPA-OP 15V was added to 0.01-1.0A 15W Medical/I.T.E.
UES15-SPA3-OP 5V was added to 0.01-3.00A 15W I.T.E.
UES15LC2-SPAZ 24V was added to 0.01-0.60A 15W I.T.E.
PoE16WC-480035 48V was added to 0.01-0.35A 16W PoE
UE18LC1-SPA 12V was added to 0.01-1.50A 18W I.T.E.
UES18LZ2-SPA 12V was added to 0.01-1.50A 18W I.T.E.
UES18LCP2-SPA 12V was added to 0.01-1.50A 18W I.T.E.
UE18LC5-SPA 12V was added to 0.01-1.50A 18W I.T.E.
UE18LC6-SPA 12V was added to 0.01-1.50A 18W I.T.E.
UE18L-SPA 12V was added to 0.01-1.50A 18W I.T.E.
UE18LC3-SPA 12V was added to 0.01-1.50A 18W I.T.E.