UES140AZ/UES140BZ-SPC
- Meets medical safety certification
- 2 MOPP isolation protection
- Leakage current ≤100μA
- Meets level 6 efficacy
- Power consumption ≤ 0.15W
- 5V/9V/12V/15V/20V/28V输出,最高140W
- Working altitude 5000 meters
- 满足USB PD3.1&PD3.0&QC4.0+&QC3.0&QC2.0快速充电协议
- Using common technologies
Product Features
| Input voltage | 80-264 volts AC | Working temp. | 0 ~ 40 ℃ |
| Input Current | 2.5A, under 90VAC input condition | Storage temperature | -40 ~ 80℃ |
| Altitude | 5000 meter | (I.e. | 10~90% RH, non-condensing |
| Standby power consumption | ≤0.15W | mean time between failures | At 25°C ambient temperature, the maximum load working MTBF is 10 hours (according to MIL-HDBK-217 standard) |
| weight | 340 g | Mechanical specifications | 121(L) 66(W) 32(H) mm |
| Application places | Suitable for medical, information and information equipment power adapters | Safety standards | CB(IEC60601-1/IEC60601-1-11/IEC60950-1/IEC62368-1)、TuV-SUD/Mark(EN60601-1/EN60601-1-11)、UL(ANSI/AAMI ES60601-1/60601-1-11/CAN/CSA C22.0 NO.60601-1/UL60950-1/UL62368-1/CAN/CSA C22.0 NO.60950-1)、TuV-SUD(IEC62368-1)、RCM(AS/NZS 60950.1)、CE(EN62368)、CCC(GB4943.1)、FCC(FCC PART 15) |
| model | Voltage(V) | Current (A) | Power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
UES140AZ-SPC UES140BZ-SPC | 5.0 | 0.01-3.00 | 15 | 300 | ± 5% | Linear regulation: ±1% Load regulation: ±5% | 82.0 % | ≤3 seconds |
| 9.0 | 0.01-3.00 | Twenty-seven | 300 | ± 5% | 86.8 % | ≤3 seconds | ||
| 12.0 | 0.01-3.00 | Thirty-six | 300 | ± 5% | 87.5 % | ≤3 seconds | ||
| 15.0 | 0.01-3.00 | 45 | 300 | ± 5% | 88.0 % | ≤3 seconds | ||
| 20.0 | 0.01-5.00 | 100 | 300 | ± 5% | 90.0 % | ≤3 seconds | ||
| 28.0 | 0.01-5.00 | 140 | 300 | ± 5% | 92.0 % | ≤3 seconds |
| Input voltage | 80-264 volts AC | Working temp. | 0 ~ 40 ℃ |
| Input Current | 2.5A, under 90VAC input condition | Storage temperature | -40 ~ 80℃ |
| Altitude | 5000 meter | (I.e. | 10~90% RH, non-condensing |
| Standby power consumption | ≤0.15W | mean time between failures | At 25°C ambient temperature, the maximum load working MTBF is 10 hours (according to MIL-HDBK-217 standard) |
| weight | 340 g | Mechanical specifications | 121(L) 66(W) 32(H) mm |
| Application places | Suitable for medical, information and information equipment power adapters | Safety standards | CB(IEC60601-1/IEC60601-1-11/IEC60950-1/IEC62368-1)、TuV-SUD/Mark(EN60601-1/EN60601-1-11)、UL(ANSI/AAMI ES60601-1/60601-1-11/CAN/CSA C22.0 NO.60601-1/UL60950-1/UL62368-1/CAN/CSA C22.0 NO.60950-1)、TuV-SUD(IEC62368-1)、RCM(AS/NZS 60950.1)、CE(EN62368)、CCC(GB4943.1)、FCC(FCC PART 15) |
| model | Voltage(V) | Current (A) | Power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
UES140AZ-SPC UES140BZ-SPC | 5.0 | 0.01-3.00 | 15 | 300 | ± 5% | Linear regulation: ±1% Load regulation: ±5% | 82.0 % | ≤3 seconds |
| 9.0 | 0.01-3.00 | Twenty-seven | 300 | ± 5% | 86.8 % | ≤3 seconds | ||
| 12.0 | 0.01-3.00 | Thirty-six | 300 | ± 5% | 87.5 % | ≤3 seconds | ||
| 15.0 | 0.01-3.00 | 45 | 300 | ± 5% | 88.0 % | ≤3 seconds | ||
| 20.0 | 0.01-5.00 | 100 | 300 | ± 5% | 90.0 % | ≤3 seconds | ||
| 28.0 | 0.01-5.00 | 140 | 300 | ± 5% | 92.0 % | ≤3 seconds |