- Home
- About UE
- UE News
- Products
- Model
-
Open frame
-
Wall plug
-
Desktop
- Featured Products
-
UES120-SPAZ-OP
-
UES310D-SPAZ
-
PoE24
-
PoE90-560161
- R & D Center
- Join Us
- Contact Us
UES100LCP2-SPC
- Compliant with communications, medical safety certifications
- 2 MOPP isolation protection
- Leakage current ≤ 100μA
- Standby power consumption≤0.15W
- 5V/9V12V/15V/20V 输出,最高100W
- Working altitude 5000 meters
- Interchangeable plug
- GAN technology
- Compliant with USB PD3.0, PPS, QC3.0, and QC2.0 fast charging protocols.
- Meets home medical standards
- Application areas: monitors, electric hospital beds, electric wheelchairs, scanners, brain stimulators, X-rays, traditional Chinese medicine physical therapy equipment, medical equipment with lithium batteries, etc.
Product Features
| Input voltage | 80-264VAC | Working temp. | 0 ~ 40 ℃ | |
| Input Current | 1.8A,In 80VAC under input conditions | Storage temperature | -40 ~ 80℃ | |
| Working altitude | 5000 meter | (I.e. | 10~90%RH, no condensation | |
| Standby power consumption | 0.15W MAX | mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard) | |
| weight | 290g ± 10g | Mechanical specifications | 97.0(L) 34.0(W) 57.0(H)mm | |
| Application places | Suitable for charging communication, medical and other equipment | Safety standards | CE(EN62368-1)、CB(IEC62368-1/IEC60950-1/ IEC60601-1/60601-1-11)、UL( ANSI / AAMI ES60601-1/60601-1-11/CAN / CSA-C22.2 NO.60601-1/UL62368)、TuV SUD/Mark(EN60601-1/EN60601-1-11) | |
| model | Voltage (V) | Current (A) | power | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES100LCP2-SPC | 5.0 | 0.01-3.00 | 15.00 | 200 | ± 5% | Linear adjustment rate: ± 1% Load: ± 5% | 82.0 % | ≤3s |
| 9.0 | 0.01-3.00 | 27.00 | 200 | ± 5% | 86.8 % | ≤3s | ||
| 12.0 | 0.01-3.00 | 36.00 | 200 | ± 5% | 87.5 % | ≤3s | ||
| 15.0 | 0.01-3.00 | 45.00 | 200 | ± 5% | 88.00 % | ≤3s | ||
| 20.0 | 0.01-5.00 | 100.00 | 250 | ± 5% | 89.00 % | ≤3s |
| Input voltage | 80-264VAC | Working temp. | 0 ~ 40 ℃ | |
| Input Current | 1.8A,In 80VAC under input conditions | Storage temperature | -40 ~ 80℃ | |
| Working altitude | 5000 meter | (I.e. | 10~90%RH, no condensation | |
| Standby power consumption | 0.15W MAX | mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 100,000 hours (according to MIL-HDBK-217 standard) | |
| weight | 290g ± 10g | Mechanical specifications | 97.0(L) 34.0(W) 57.0(H)mm | |
| Application places | Suitable for charging communication, medical and other equipment | Safety standards | CE(EN62368-1)、CB(IEC62368-1/IEC60950-1/ IEC60601-1/60601-1-11)、UL( ANSI / AAMI ES60601-1/60601-1-11/CAN / CSA-C22.2 NO.60601-1/UL62368)、TuV SUD/Mark(EN60601-1/EN60601-1-11) | |
| model | Voltage (V) | Current (A) | power | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES100LCP2-SPC | 5.0 | 0.01-3.00 | 15.00 | 200 | ± 5% | Linear adjustment rate: ± 1% Load: ± 5% | 82.0 % | ≤3s |
| 9.0 | 0.01-3.00 | 27.00 | 200 | ± 5% | 86.8 % | ≤3s | ||
| 12.0 | 0.01-3.00 | 36.00 | 200 | ± 5% | 87.5 % | ≤3s | ||
| 15.0 | 0.01-3.00 | 45.00 | 200 | ± 5% | 88.00 % | ≤3s | ||
| 20.0 | 0.01-5.00 | 100.00 | 250 | ± 5% | 89.00 % | ≤3s |