- Home
- About UE
- UE News
- Products
- Model
-
Open frame

-
Wall plug

-
Desktop

- Featured Products
-
UES120-SPAZ-OP

-
UES310D-SPAZ

-
PoE24

-
PoE90-560161

- R & D Center
- Join Us
- Contact Us
UES100DZ-SPA
- Meets medical safety certification
- 2 MOPP isolation protection
- PF>0.95@230VAC full load
- Leakage current ≤ 100μA
- Energy Efficiency level VI
- Standby power consumption≤0.21W
- Peak load: 216W (10s)
- Working altitude 5000 meters
- 4 Summary communication input
Product Features
| Input voltage | 80-264VAC | Working temp. | -30~70℃ (refer to the derating curve for 40~70℃) | |
| Input Current | 2.5A, under 90VAC input condition | Storage temperature | -40 ~ 85℃ | |
| Standby power consumption | 0.15W MAX | (I.e. | 10~90% RH, non-condensing | |
| mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 50,000 hours (according to MIL-HDBK-217 standard) | |||
| weight | 420g | Mechanical specifications | 145.2(L) 65.8(W) 31.5(H)mm | |
| Application places | Suitable for medical and information equipment power adapters | Safety standards |
| |
| model | Voltage (V) | Current (A) | power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES100D”Z”-XXXYYYSPA | 12.00 | 0.01-7.50 | 90.00 | 150 | ± 5% | Linear adjustment rate: ± 1% Load regulation: ±5% | 88.0% | ≤3s |
| 12.1-13.0 | 0.01-6.92 | 90.00 | 150 | 88.0% | ≤3s | |||
| 13.1-14.0 | 0.01-6.43 | 90.00 | 150 | 88.0% | ≤3s | |||
| 14.1-15.0 | 0.01-6.00 | 90.00 | 200 | 88.0% | ≤3s | |||
| 19.0 | 0.01-5.00 | 95.00 | 200 | 88.0% | ≤3s | |||
| 19.1-20.0 | 0.01-5.00 | 100.00 | 200 | 88.0% | ≤3s | |||
| 20.1-21.0 | 0.01-4.76 | 100.00 | 300 | 88.0% | ≤3s | |||
| 21.1-22.0 | 0.01-4.54 | 100.00 | 300 | 88.0% | ≤3s | |||
| 22.1-23.0 | 0.01-4.35 | 100.00 | 300 | 88.0% | ≤3s | |||
| 23.1-24.0 | 0.01-4.17 | 100.00 | 300 | 88.0% | ≤3s |
| Input voltage | 80-264VAC | Working temp. | -30~70℃ (refer to the derating curve for 40~70℃) | |
| Input Current | 2.5A, under 90VAC input condition | Storage temperature | -40 ~ 85℃ | |
| Standby power consumption | 0.15W MAX | (I.e. | 10~90% RH, non-condensing | |
| mean time between failures | At an ambient temperature of 25°C, the mean time between failures at maximum load is 50,000 hours (according to MIL-HDBK-217 standard) | |||
| weight | 420g | Mechanical specifications | 145.2(L) 65.8(W) 31.5(H)mm | |
| Application places | Suitable for medical and information equipment power adapters | Safety standards |
| |
| model | Voltage (V) | Current (A) | power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and Negative Adjustment Rates | Average efficiency | Start delay time |
| UES100D”Z”-XXXYYYSPA | 12.00 | 0.01-7.50 | 90.00 | 150 | ± 5% | Linear adjustment rate: ± 1% Load regulation: ±5% | 88.0% | ≤3s |
| 12.1-13.0 | 0.01-6.92 | 90.00 | 150 | 88.0% | ≤3s | |||
| 13.1-14.0 | 0.01-6.43 | 90.00 | 150 | 88.0% | ≤3s | |||
| 14.1-15.0 | 0.01-6.00 | 90.00 | 200 | 88.0% | ≤3s | |||
| 19.0 | 0.01-5.00 | 95.00 | 200 | 88.0% | ≤3s | |||
| 19.1-20.0 | 0.01-5.00 | 100.00 | 200 | 88.0% | ≤3s | |||
| 20.1-21.0 | 0.01-4.76 | 100.00 | 300 | 88.0% | ≤3s | |||
| 21.1-22.0 | 0.01-4.54 | 100.00 | 300 | 88.0% | ≤3s | |||
| 22.1-23.0 | 0.01-4.35 | 100.00 | 300 | 88.0% | ≤3s | |||
| 23.1-24.0 | 0.01-4.17 | 100.00 | 300 | 88.0% | ≤3s |
Product information
Compare—
Related Products
model
Output Voltage
Output Current
power
Application industry
Data sheet
Compared