UE05LCP-SPA

  • Compliant with communications and medical safety certifications
  • 2 MOPP isolation protection
  • Leakage current ≤ 10
  • DOE efficiency level V
  • Standby power consumption≤0.3W
  • Working altitude 5000 meters
  • 5V and 6V output, highest5W
Product Features
Input voltage90-264VACWorking temp.0〜45 ℃        
Input Current0.2A, under 100VAC input conditionsStorage temperature-20~60℃       
Output voltage range± 8%Working humidity10~90%RH, no condensation       
Standby power consumption0.3W MAXmean time between failures > 100,000 hours MIL-HDBK-217 at 25°C ambient temperature.       
weight75gMechanical specifications

70.0(L)  30.2(W)  52.0(H)mm

      
Application placesSuitable for medical and ITE equipment power adaptersSafety standardsCB(IEC60601-1)、TUV-SUD Mark(EN60601-1)、CCC(GB4943.1)、NRTL(ANSI/AAMI ES6001-1 CAN/CSA C22.2 NO.60601-1)      
            
modelVoltage(V)Current (A)Rated powerRipple and noise (maximum)Voltage toleranceLinear and load regulationAverage efficiencyStart delay time
UE05LCP-XXXYYYSPA5.00.01-1.005.00W200mVpk-pk ±8%

Line: ±5%

Load regulation: ±5%

68.17%3S
6.00.01-0.804.80W200mVpk-pk ±8%72.02%3S
Input voltage90-264VACWorking temp.0〜45 ℃        
Input Current0.2A, under 100VAC input conditionsStorage temperature-20~60℃       
Output voltage range± 8%Working humidity10~90%RH, no condensation       
Standby power consumption0.3W MAXmean time between failures > 100,000 hours MIL-HDBK-217 at 25°C ambient temperature.       
weight75gMechanical specifications

70.0(L)  30.2(W)  52.0(H)mm

      
Application placesSuitable for medical and ITE equipment power adaptersSafety standardsCB(IEC60601-1)、TUV-SUD Mark(EN60601-1)、CCC(GB4943.1)、NRTL(ANSI/AAMI ES6001-1 CAN/CSA C22.2 NO.60601-1)      
            
modelVoltage(V)Current (A)Rated powerRipple and noise (maximum)Voltage toleranceLinear and load regulationAverage efficiencyStart delay time
UE05LCP-XXXYYYSPA5.00.01-1.005.00W200mVpk-pk ±8%

Line: ±5%

Load regulation: ±5%

68.17%3S
6.00.01-0.804.80W200mVpk-pk ±8%72.02%3S

Product information

Related Products
model
Output Voltage
Output Current
power
Application industry
Data sheet
Compared
UE03L-SPAZ 9V was added to 0.01-0.3A 2.7W Medical/I.T.E.
UE05LZ4-SPA/UE05LZ5-SPA 5V was added to 0.01-1.0A 5W Medical/I.T.E.
UES05LZ6-SPA 5V / 6V was added to 0.01-1.0A 5W Medical/I.T.E.
UE05LCP-SPA 5V / 6V was added to 0.01-1.00A 5W Medical/I.T.E.
UE05L-SPAV 5V / 6V was added to 0.01-1.00A 5W Medical/I.T.E.
UE05LC3-SPA 5V / 6V was added to 0.01-1.0A 5W Medical/I.T.E.
UES06WZ-SPA 4.2-12V was added to 0.01-1.2A 6W Medical/I.T.E.
UES06WNCP1-SPA 4.2-12V was added to 0.01-1.2A 6W Medical/I.T.E.
UES06-SPA-OP 5.25V was added to 0.01-1.2A 6W I.T.E.
UE08-SPA-OP 12V was added to 0.01-0.70A 8W I.T.E.
UES10LZ1-SPA/UES10LZ2-SPA 5V was added to 0.01-2.0A 10W Medical/I.T.E.
UES10WCP-SPC-M2 5V was added to 0.10-1.00A 10W I.T.E.
UE12LC1-SPAZ 12V was added to 0.01-1.00A 12W I.T.E.
UES12D1-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UES12LZ5-SPA 15V / 19V was added to 0.01-0.8A 12W Household/I.T.E.
UES12LCP1-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UES12L1-SPAZ 12V was added to 0.01-1.00A 12W I.T.E.
PoE12WC-480025 48V was added to 0.01-0.25A 12W PoE
UES12LCP-SPA/UES12LCP-SPC 4-24V was added to 0.01-2.0A 12W Medical/I.T.E.
UES12-120100SPA1-OP 12V was added to 0.01-1.00A 12W I.T.E.
UES12WU2-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UES12LCP2-SPA 4-24V was added to 0.01-2.00A 12W Medical/I.T.E.
UE12LC2-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UE12-120100SPA2-OP 12V was added to 0.01-1.00A 12W I.T.E.
UES12LZ11-SPA 12V was added to 0.01-1.00A 12W Medical/I.T.E.
UES12LD4-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UES12WV1-SPA 12V was added to 0.01-1.00A 12W I.T.E.
UES15LZ-SPAZ/UES15LZ1-SPAZ 5V was added to 0.01-3.0A 15W Medical/I.T.E.
UES15-SPA3-OP 5V was added to 0.01-3.00A 15W I.T.E.
UES15LC2-SPAZ 24V was added to 0.01-0.60A 15W I.T.E.