Features * Active power factor correction; * Protections;Short circuit/Over load;
Technical data Input Voltage Range:90-264VAC Power Factor:typical 0.95min(at input 115VAC,full load) THD:<15% Typical Efficiency:80% min (at input 230VAC,full load) |
Environmental specification/EMC Operation temp:20-40”ę Storage temp:-40-85”ę Humidity:10-90%RH MTBF calculation:Up to 50,000 Hours Lifetime Safety approval:Meet UL8750(UL60950),EN61347,CCC EMC standards:CISPR15; FCC 47CFR-Part15B |
Products
| Model No. |
Output |
Tol. |
PF. |
Eff. |
| UEL009-S051C016-T8-OP |
46~51V, 0.16A |
”Ą5% |
0.95 |
80% |
| UEL009-S051C027-T8-OP |
46~51V, 0.27A |
”Ą5% |
0.95 |
80% |
| UEL009-S051C032-T8-OP |
46~51V, 0.32A |
”Ą5% |
0.95 |
80% |
| UEL009-S051C040-T8-OP |
46~51V, 0.40A |
”Ą5% |
0.95 |
80% |
| UEL009-S051C046-T8-OP |
46~51V, 0.46A |
”Ą5% |
0.95 |
80% |
Note:1ӢEfficiency is measured at 230VAC; 2ӢPower Factor is measured at 115VAC .
Mechanical specification 290mm(L) x 22mm(W)x13.5mm(H)
|